Simulation
Flow Through Packed Bed
Department of Chemical engineering NITK presents...
CONTINUE..
What would you like to do.
Flow through Packed Bed
VIRTUAL LAB @ NITK
- Click on Label Tab to see the Experimental Setup.
- Click on Setup Tab to Configure Experimental Setup.
- Now click on Experiment Tab to perform the experiment.
- To start the experiment first switch ON the pump by clicking the GREEN button on the pump.
- Once the pump is turned on Setup Tab will be disabled and will be enabled only if pump is OFF. Click on RED button on pump to switch OFF pump.
- To set the required flowrate click and hold on Main valve and drag in AntiClockWise direction for opening Valve and ClockWise direction for closing the Valve.
- Note the change in limb level of manometer. h1 and h2 are corresponding Manometric Limb heights from reference level.
- Click on Add current readings button to record the reading in Observation table.
- Click on Observations button to see the Observation table. Click again to hide the Table.
- Click on Experimental Data button to see the Experimental Data. Click again to hide.
- If you get Manometer Overflow Error, goto Setup Tab and change the Manometer.
- To Evaluate experiment click on title Flow Through Packed Bed.
- Click on Data tab to configure Experimental data.
- Click on Observation tab to Enter your Observations. Specify number of sets of readings.
- Click on Evaluate button to see the Results.
- To perform experiment again click on the Flow Through Packed Bed.

Length of the Packed Bed:
Nominal diameter of the packed bed:
cmProcess fluid:
Manometric fluid:
Length of the packed bed:
cmNominal diameter of the packed bed:
Select packing material:
Process fluid:
Manometric fluid:
Number of sets of readings:
Flowrate(lpm) | Manometric Pressure drop | Reynolds no. | Co-efficient of Discharge |
---|
Reynolds no. | Co-efficient of Discharge |
---|





























































NOTE:
ROTAMETER READING:
00.00
LPM
h1:
35.00
cm
h2:
35.00
cm
Observations
×Click on the rows which you want to delete
Process fluid | Manometric fluid | Flowrate(lpm) | h1(cm of Manometric fluid) | h2(cm of Manometric fluid) |
---|
Email is required
Experimental Data
Length of Packed Bed:
meter(s)
Nominal Pipe Diameter:
inch
Actual Pipe Diameter:
m
Packing Material:
Sphericity:
Specific Surface Area
m2/m3
Void Volume:
mL
Process Fluid:
Density of Process Fluid:
Kg per Cubic meter
Viscoscity of Process Fluid:
centiPoise
Manometric Fluid:
Density Manometric Fluid:
Kg per Cubic meter
Manometric Fluid is about to Overflow.
Change the Manometer to Mercury.
Trial =